Affiliation:
1. 1 Department of Ophthalmology, Tsukazaki Hospital, Himeji, Japan 2 Department of Technology and Design Thinking for Medicine, Hiroshima University Graduate School of Biomedical and Health Sciences, Hiroshima, Japan
2. 1 Department of Ophthalmology, Tsukazaki Hospital, Himeji, Japan
Abstract
Abstract
We compared the visual performance of a bifocal intraocular lens (IOL) (ZMB00) and an extended-depth-of-focus (EDOF) IOL (ZXR00V) by evaluating postoperative parameters at 10 weeks after the last surgery in cataract patients who underwent bilateral ZMB00 or ZXR00V implantation between 2011 and 2020. The right and left lenses were implanted within 3 months of each other. The study enrolled 1536 eyes from 768 patients; the ZMB00 group comprised 1326 eyes of 663 patients (age: 67.0 ± 7.8 years; female/male, 518/145), and the ZXR00V group comprised 210 eyes of 105 patients (age: 67.8 ± 6.9 years; female/male, 39/66). A linear mixed-effects model using data for both eyes, with strict adjustments for sex, age, subjective refraction spherical equivalent, subjective refraction cylinder, corneal astigmatism, axial length, corneal higher-order aberrations and pupil diameter, ensured statistical validity. Uncorrected near visual acuity, corrected near visual acuity, and near spectacle independence were significantly better in the ZMB00 group (p < 0.00068, Wald test) than in the ZXR00V group. Contrast sensitivity (visual angle of the test target: 4.0°/2.5°/1.6°/1.0°/0.7°) and contrast sensitivity with glare (4.0°/2.5°/1.6°/1.0°/0.7°) were significantly better in the ZXR00V group (p < 0.00068, Wald test) than in the ZMB00 group. Uncorrected intermediate visual acuity, contrast sensitivity with glare (6.3°), and the 25-item National Eye Institute Visual Function Questionnaire (VFQ-25) scores for General Vision were slightly but significantly better in the ZXR00V group than in the ZMB00 group (p < 0.05, Wald test). At high-performance levels, the two IOL groups had different characteristics regarding various visual performance parameters.
Publisher
Research Square Platform LLC
Reference54 articles.
1. Vision 2020: the cataract challenge;Foster A;Community Eye Health,2000
2. Population aging and migration – history and UN forecasts in the EU-28 and its east and south near neighborhood – one century perspective 1950–2050;Jakovljevic MM;Glob Health,2018
3. Cataract surgery from 1918 to the present and future-just imagine!;Olson RJ;Am J Ophthalmol,2018
4. Multifocal versus monofocal intraocular lenses after cataract extraction;Silva SR;Cochrane Database Syst Rev,2016