Evaluation of the Efficiency and Safety of a 27-gauge 20,000 cuts per minute Vitreous Cutter

Author:

Doi Yuta1,Muraoka Yuki1,Tsujikawa Akitaka1

Affiliation:

1. Kyoto University Graduate School of Medicine

Abstract

Abstract Purpose The aim of this study was to evaluate the efficiency and safety of a 27-gauge (G) 20,000 cuts per minute (cpm) vitreous cutter in clinical settings. Methods This was a retrospective and observational study of 40 eyes of 40 patients with idiopathic epiretinal membrane (ERM). Twenty patients (20 eyes) were treated using a 27G 10,000-cpm vitreous cutter (Advanced ULTRAVIT® Probe, Alcon), whereas the remaining 20 patients (20 eyes) were treated using a 27G 20,000-cpm cutter (Hypervit® dual-blade probe, Alcon). All the surgeries were performed by the same surgeon (YM). The time from the start of vitrectomy to the start of ERM peeling was independently measured by two separate examiners using digital videos of each surgery. The average duration of vitrectomy was calculated for each patient. Additionally, the data of the patients in the two groups were extracted from their medical and surgical records and compared. Results The time from the initiation of vitrectomy until the start of ERM peeling was 184 ± 56.9 and 152 ± 39.5 s for the 10,000-cpm and 20,000-cpm groups, respectively. The duration of vitrectomy was significantly shorter in the 20,000-cpm group than in the 10,000-cpm group (p= 0.041). Postoperative vitreous hemorrhage was observed in one patient in the 10,000-cpm group, whereas no complications were observed in the 20,000-cpm group. Conclusion In a clinical setting, the 27G 20,000-cpm vitreous cutter may have a high safety profile and higher efficacy for vitreous removal than that of the 27G 10,000-cpm vitreous cutter.

Publisher

Research Square Platform LLC

Reference14 articles.

1. 1. ã࿽࿽Machemer R (1975) Vitrectomy, a pars plana approach. Grune & Stratton, New York, USA

2. Transconjunctival sutureless 23-gauge vitrectomy;ã࿽࿽Eckardt C;Retina,2005

3. Initial experience using the transconjunctival sutureless vitrectomy system for vitreoretinal surgery;Juan 3 ã࿽࿽FujiiGY;Ophthalmology,2002

4. A new 25-gauge instrument system for transconjunctival sutureless vitrectomy surgery;Juan ï¼࿽ ã࿽࿽FujiiGY;Ophthalmology,2002

5. 25-gauge, sutureless vitrectomy and standard 20-gauge pars plana vitrectomy in idiopathic epiretinal membrane surgery: a comparative pilot study;Genovesi-Ebert ï¼࿽ ã࿽࿽RizzoS;Graefes Arch Clin Exp Ophthalmol,2006

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3