Comparison of Femoral Neck System versus Cannulated Screws for Treatment of Femoral Neck Fractures: A Systematic Review and Meta-Analysis

Author:

Jiang Jiabao1,Chen Jialei1,Xing Fei1,Liu Hao1,Xiang Zhou1

Affiliation:

1. West China Hospital of Sichuan University

Abstract

Abstract Background: Recently, some studies on the efficacy of the femoral neck system (FNS) in treating femoral neck fractures (FNFs) have been published. Therefore, a systematic review was performed to clarify the efficacy and safety of FNS versus cannulated screws (CS) for the treatment of FNFs. Method: The PubMed, EMBASE, and Cochrane databases were systematically searched for studies comparing FNS and CS fixations in FNFs. Intraoperative indicators, postoperative clinical indicators, postoperative complications, and postoperative scores were compared between the implants. Results: A total of eight studies were included in the study, involving 448 FNFs patients. The results showed that patients in FNS group were significantly lower than the CS group in the number of X-ray exposures (WMD=-10.16; 95% CI, -11.44 to -8.88; P<0.001; I2=0%), fracture healing time (WMD=-1.54; 95% CI, -2.38 to -0.70; P <0.001; I2=92%), length of femoral neck shortening (WMD=-2.01; 95% CI, -3.11 to -0.91; P <0.001; I2=0%), femoral head necrosis (OR=0.27; 95% CI, 0.08 to 0.83; P =0.02; I2=0% ), implant failure/cutout (OR=0.28; 95% CI, 0.10 to 0.82; P =0.02; I2=0%), and Visual Analog Scale Score (WMD=-1.27; 95% CI, -2.51 to -0.04; P=0.04; I2=91%). And the Harris Score was significantly higher in the FNS group than in the CS group (WMD=4.15; 95% CI, 1.00 to 7.30; P=0.01; I2=89%). Conclusions: Based on this meta-analysis, FNS shows better clinical efficacy and safety in treating FNFs compared to CS. However, due to the limited quality and number of included studies and the high heterogeneity of the meta-analysis; large samples and multicenter RCTs are needed to confirm this conclusion in the future. Level of evidence: II, Systematic review and Meta-analysis. Review registration: PROSPERO CRD42021283646.

Publisher

Research Square Platform LLC

Reference35 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3