Repeatability analysis of cardiac function parameters in gated SPECT myocardial perfusion imaging

Author:

Huang Yunxia1,Wan Qichang1,Yang Shijian1,Wang Zhongling1,Ye Ruxian2,Xu Miaoyu1,Zhou Hui1,Chen Rongjun1,Guan Xiuhong1,Li Guangming1,Wang Ziyan1

Affiliation:

1. Guangzhou Medical University

2. Jinan University

Abstract

Abstract

Background: Single Photon Emission Computed Tomography (SPECT) myocardial perfusion imaging (MPI) is a non-invasive method used to detect myocardial ischemia, which helps assess left ventricular function when used in conjunction with electrocardiogram gating. While quantitative analysis software greatly improves diagnostic precision in cardiology, it can still be affected by variations in operator technique. Purpose: To assess the reproducibility of cardiac function parameters in gated SPECT MPI. Methods: Two nuclear medicine doctors with over 3 years of experience in SPECT/CT image reading independently utilized 4DM software to measure left ventricular function parameters with the ROI delineation method recommended by the manufacturer. Initial measurements were conducted, followed by a re-measurement after one week. Measurement results obtained by the same physician during both sessions were categorized as ‘within-investigator’ consistency, while those acquired by different physicians were designated as ‘between-investigators’ consistency. Intraclass correlation coefficients (ICCs) were employed to evaluate consistency. Furthermore, Bland-Altman analysis was conducted to examine the agreement in discrepancies among different indicators. Simultaneously, the least significant changes (LSCs) and reproducibility of gated SPECT MPI were calculated and measured. Results: The intra-observer ICC values of left ventricular ejection fraction (LVEF), end-diastolic volume (EDV), end-systolic volume (ESV), and summed stress score (SSS)/summed rest score (SRS) were 0.973-0.978, 0.995-0.997, 0.983-0.988, and 0.976-0.991, respectively. The inter-observer ICC values were 0.954-0.973, 0.990-0.997, 0.973-0.991, and 0.976-0.992, respectively. Gated SPECT MPI measured by Observer 1 and Observer 2 showed very high consistency in measuring LVEF, EDV, ESV, and SSS/SRS. The results of reproducibility assessment showed that the root-mean-square standard deviation (SDRMS) of LVEF, EDV, ESV, and SSS/SRS were 1.86-2.20%, 1.16-1.27%, 0.94-1.17%, and 0.56-0.92%, respectively. The corresponding LSCs were 5.15-6.10%, 3.22-3.53%, 2.62-3.16%, and 1.54-2.54%, respectively. Conclusions: The region of interest (ROI) delineation method recommended by the device manufacturer was adopted and employed uniformly in the medical team to benefit from the repeatability measurement of cardiac function parameters in gated SPECT MPI. In addition, basic tests such as LSCs and reproducibility can be included in the quality assurance plan, which can be conducted regularly. Consequently, every medical department can establish its control framework through these fundamental experiments.

Publisher

Springer Science and Business Media LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3