Prospective evaluation of cerebrospinal fluid levels of β-Endorphin as a predictor of opioid use after scheduled cesarean delivery

Author:

Pham Amelie1,Osmundson Sarah S1,Pedowitz Alex2,Wickersham Nancy1,Sorabella Laura L1,Bruehl Stephen1

Affiliation:

1. Vanderbilt University Medical Center

2. University of Miami Leonard M. Miller School of Medicine

Abstract

Abstract Background Prior laboratory work indicates that lower endogenous opioid function is associated with greater analgesic and subjective responses to opioid analgesics. We evaluated whether lower preoperative cerebrospinal fluid (CSF) levels of the analgesic endogenous opioid β-Endorphin (BE) were associated with increased opioid use after cesarean delivery (CD). Methods We enrolled 136 pregnant women without opioid use or chronic pain who were undergoing CD under regional anesthesia. Preoperatively, participants completed validated pain measures and biospecimens were collected to assess BE levels in plasma and CSF. Postoperatively, pain measures at 48 hours and 2 weeks postpartum were assessed. We evaluated the association between CSF BE levels and total opioid use (in morphine milligram equivalents; MMEs) using linear regression controlling for confounding factors (primary analysis). In secondary analyses, we examined: 1) associations between plasma BE levels and total opioid use, and 2) associations between CSF and plasma BE levels and secondary outcomes (inpatient versus outpatient opioid use, pain intensity). Results Participants completed surveys with 100% response rate. The majority were non-Hispanic white (65%), college educated (58%), had private insurance (71%), and had a prior cesarean delivery (69%). Psychiatric diagnoses (depression or anxiety) were common, both currently (22%) and in the past (26%).The median total opioid use across the inpatient and 2-week postpartum follow-up period was 89.1 milligram morphine equivalents (IQR 25–138). Preoperative cerebrospinal fluid β-Endorphin levels were not associated with total opioid use (beta = -0.05, SE 0.45, p = 0.64). Similar findings were noted for plasma β-Endorphin levels. cerebrospinal fluid β-Endorphin levels were only weakly correlated with plasma β-Endorphin levels (r = 0.30, p < .01). Preoperative cerebrospinal fluid and plasma β-Endorphin levels were both positively associated with postpartum pain measures (cerebrospinal fluid: at 48 hours, beta = 0.19, SE 0.16, p < 0.05; Plasma: at 48-hours, beta = 0.02, SE 0.03, p = 0.02, and at 2-weeks, beta = 0.27, SE 0.03, p < 0.01). Conclusions Lower preoperative cerebrospinal fluid levels of β-Endorphin are not associated with increased opioid analgesic use after scheduled cesarean delivery. It is possible that unassessed variability in baseline opioid receptor sensitivity may have confounded ability to test associations between β-Endorphin levels and opioid use outcomes.

Publisher

Research Square Platform LLC

Reference33 articles.

1. Size and distribution of the global volume of surgery in 2012;Weiser TG;Bull World Health Organ,2016

2. The Case for Standardizing Cesarean Delivery Technique: Seeing the Forest for the Trees;Dahlke JD;Obstet Gynecol,2020

3. An experimental paradigm for the prediction of Post-Operative Pain (PPOP);Landau R;J Vis Exp

4. Persistent Pain After Cesarean Delivery and Vaginal Delivery: A Prospective Cohort Study;Kainu JP;Anesth Analg,2016

5. Predictors for Moderate to Severe Acute Postoperative Pain after Cesarean Section;Borges NC;Pain Res Manag,2016

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3