Affiliation:
1. China University of Mining and Technology
2. Xuzhou College of Industrial Technology
Abstract
Abstract
The hazard of stray current attracts more and more attention due to the potential infrastructure failure caused by the electrochemical corrosion. In view of the poor insulation performance and lack of stray current collection system in the metro depot, stray current leakage becomes particularly evident in this area. In order to evaluate the corrosion risk of buried metal pipeline surrounding metro depot, an assessment model for interference scope induced by stray current is proposed in this paper. The distribution of stray current is calculated based on the resistive network by considering different boundary conditions in different areas of metro depot, and the interference scope is assessed by surface potential gradient for corrosion risk of corroded pipeline. Moreover, the characteristics of surface potential gradient distribution in different areas of metro depot and the influence of electrical parameters are analyzed. Finally, the proposed model is verified through CDEGS-based simulation and experimental results.
Publisher
Research Square Platform LLC
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献