Handheld ultrasound device in the assessment of the uterus and adnexa

Author:

Araujo Karla Galvão1ORCID,Adriana Yoshida,Machado Helymar Costa,Sarian Luis Otávio,Derchain Sophie

Affiliation:

1. Universidade Estadual de Campinas

Abstract

Abstract Purpose To assess the performance of the handheld ultrasound device (HUD) Butterfly-iQ compared to conventional transvaginal ultrasonography (US) in characterizing measurement and morphological aspects of the normal and abnormal uterus and adnexa. Methods This prospective accuracy study included 162 patients evaluated with transabdominal HUD, followed by conventional transvaginal US, between May 2021 and September 2022. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were calculated to evaluate gynecological pelvic findings, with conventional US as the reference standard. The intraclass coefficient measured the reliability of pelvic findings measurements and the Kappa coefficient assessed the agreement of categorical variables between the two ultrasound modalities. Results For numerical variables, there was good to excellent agreement for uterine longitudinal diameter, uterine volume, endometrial thickness, fibroid larger diameter, crown–rump length, ovarian volume, and adnexal alteration maximum diameter, with intraclass coefficients ranging between 0.76 and 0.95. The sensitivity and specificity of HUD were 88.1% and 97.6%, respectively, for detecting uterine volume larger than 160 cm³, 84.4% and 99.7% for fibroids larger than 20 mm, and 68.7% and 95.9% for adnexal masses larger than 30 mm. Regarding the evaluation of small structures, HUD showed sensitivity and specificity of 12.5% and 99.3% for identifying intracavitary contents, 22.9% and 99.7% for fibroids smaller than 20 mm, and 33.3% and 98.5% for adnexal alterations smaller than 30 mm. Kappa coefficients for differentiating the position of the uterus, the location of the fibroids, and the type of adnexal mass were 0.68, 0.78, and 0.84, respectively. The data included ten cases of early pregnancy. The sensitivity and specificity were 100% for identifying intrauterine and adnexal pregnancies, and 66.7 and 100%, respectively, for characterizing images compatible with ovular remains. Conclusion Transabdominal HUD Butterfly-iQ and transvaginal conventional US demonstrated good to excellent agreement in measuring pelvic findings. HUD performed well in identifying early pregnancy, and gynecological pelvic conditions such as fibroids larger than 20 mm but exhibited poor performance in identifying small alterations of the uterus and adnexa.

Publisher

Research Square Platform LLC

Reference25 articles.

1. The History of US: From Bats and Boats to the Bedside and Beyond;Kaproth-Joslin KA;RSNA Centennial Article Radiographics,2015

2. Handheld Point-of-Care Ultrasound Probes: The New Generation of POCUS;Baribeau Y;J Cardiothorac Vasc Anesth,2020

3. Task shifting for point of care ultrasound in primary healthcare in low- and middle-income countries-a systematic review (;Abrokwa SK;EClinicalMedicine,2022

4. Point-of-Care Ultrasonography;Arnold MJ;Am Fam Physician,2020

5. Jain V, O'Quinn C, Van den Hof M Guideline No. 421: Point of Care Ultrasound in Obstetrics and Gynaecology. J Obstet Gynaecol Can 43(9):1094-99. 6., Andersen CA, Holden S, Vela J, Hathleff MF, Jensen MB (2021) (2019) Point-of-Care Ultrasound in General Practice: A Systematic Review. Ann Fam Med 17(1): 61 – 9

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3