Abstract Objective Given the ability of ultrasound imaging (USI) to depict tissue-specific morphological changes before the onset of pain and before the point of irreversible structural damage, USI could play a fundamental role in earlier detection and assessment of foot osteoarthritis. Current guidelines require further refinement of anatomical landmarks to establish a standardised imaging procedure to improve interpretability and reproducibility between studies evaluating the first metatarsophalangeal joint (MTPJ). The aims were to develop an USI acquisition procedure and grading system to examine OA features in the first MTPJ and to determine intra-examiner and inter-examiner reliability of a newly developed USI acquisition procedure.Design Thirty participants with first MTPJ osteoarthritis confirmed radiographically with the use of the La Trobe Foot Atlas were included. An experienced sonographer applied a newly developed USI procedure to examine the following features: joint effusion, synovial hypertrophy, synovitis, joint space narrowing, osteophytes, and cartilage thickness. To determine intra and inter-examiner reliability an experienced radiologist and sonographer applied the developed grading system to the images acquired from two imaging sessions. Intra-examiner and inter-examiner reliability were calculated using intraclass correlation coefficients (ICC).Results ICCs for intra-examiner between session reliability ranged from 0.58 to 0.92 for semiquantitative grading and 0.39 to 0.94 for continuous measures. Joint effusion and osteophytes achieved the highest intra-examiner reliability (ICC = 0.78–0.94). ICCs for session one inter-examiner reliability ranged from 0.61 to 1.0 for semiquantitative grading, all continuous measures had an ICC of 1. ICCs for session two inter-examiner reliability ranged from 0.55 to 1.0 for semiquantitative grading and 0.9 to 0.97 for continuous measures. Inter-examiner reliability was good for grading joint effusion (ICC = 0.55–0.62) and was excellent for all other USI features (ICC = 0.77-1.0).Conclusion The USI acquisition procedure and grading system are reliable in evaluating first MTPJ osteoarthritis features in participants with radiologically confirmed osteoarthritis. The study will inform the methodological development of an ultrasound atlas for grading the degree of osteoarthritic change in the first MTPJ.

Publisher

Research Square Platform LLC

Reference38 articles.

1. Musculoskeletal ultrasound: technical guidelines;Martinoli C;Insights into imaging,2010

2. Should oligoarthritis be reclassified? Ultrasound reveals a high prevalence of subclinical disease;Wakefield R;Ann Rheum Dis,2004

3. Ultrasound imaging for the rheumatologist XXXII. Sonographic assessment of the foot in patients with psoriatic arthritis;Delle Sedie A;Clin Exp Rheumatol,2011

4. EULAR recommendations for the use of imaging in the clinical management of peripheral joint osteoarthritis;Sakellariou G;Ann Rheum Dis,2017

5. Comparison of diagnostic performance of semi-quantitative knee ultrasound and knee radiography with MRI: Oulu knee osteoarthritis study;Podlipská J;Sci Rep,2016