The Tolerance of Refractive Errors of Extended Depth of Focus Intraocular Lens in Patients with Previous Corneal Refractive Surgery

Author:

Zheng Hansong1,Tan Qian2,Zhou Suowang1,Luo Wenjing2,Ortega-Usobiaga Julio3,Wang Li4,Wang Yong1

Affiliation:

1. Aier School of Ophthalmology, Central South University

2. Aier Eye Hospital of Wuhan University

3. Clinica Baviera

4. The Department of Ophthalmology, Baylor College of Medicine, Cullen Eye Institute

Abstract

Abstract Purpose To evaluate the tolerance of refractive errors and visual outcomes of extended depth of focus intraocular lens (EDOF IOLs) in patients with previous corneal refractive surgery for myopia. Methods Patients from Wuhan Aier Eye Hospital with previous myopia excimer laser correction underwent cataract surgery and implantation of an EDOF IOL. The follow-up period was three months. The uncorrected distance, intermediate, and near visual acuities (UDVA, UIVA, UNVA), corrected distance visual acuity (CDVA), spherical equivalent (SE), defocus curve, optical quality, including modulation transfer functions (MTF) and Strehl ratio (SR), National Eye Institute Visual Functioning Questionnaire-14 for Chinese people (VF-14-CN), spectacle independence, and dysphotopsia were assessed. Results At the final visit, UDVA, CDVA, UIVA, and UNVA (logMAR) were 0.07 ± 0.09, 0.01 ± 0.04, 0.10 ± 0.08, 0.20 ± 0.11, respectively. The mean spherical equivalent (SE) was ± 0.75 ± 0.49D, where 42% (21 eyes) were within ± 0.50D, 70% (35 eyes) were within ± 1.00D, and 98% (49 eyes) were within ± 1.50D. The defocus curve showed that visual acuity could reach 0.1 in the refractive range of 0 ~ -1.5D. SR and MTF values of 10, 15, 20, 35, and 30 c/d spatial frequency were measured with a 3 mm pupil diameter after removing the influence of low-order aberrations, which were all higher than the values before the operation. The mean VF-14-CN questionnaire score was 51.02 ± 2.95 out of 56. Conclusion The EDOF IOLs have a certain tolerance for refractive errors, and they are recommended for patients with prior myopia excimer laser surgery to achieve satisfactory visual performance.

Publisher

Research Square Platform LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3