Abstract

Purpose The sphingosine-1-phosphate receptor-1 (S1PR1) is involved in regulating responses to neuroimmune stimuli. There is a need for S1PR1-specific radioligands with clinically suitable brain pharmcokinetic properties to complement existing radiotracers. This work evaluated a promising S1PR1 radiotracer, [18F]TZ4877, in nonhuman primates. Procedures: [18F]TZ4877 was produced via nucleophilic substitution of tosylate precursor with K[18F]/F followed by deprotection. Brain PET imaging data were acquired with a Focus220 scanner in two Macaca mulatta (6, 13 years old) for 120–180 min following bolus injection of 118–163 MBq [18F]TZ4877, with arterial blood sampling and metabolite analysis to measure the parent input function and plasma free fraction (fP). Each animal was scanned at baseline, 15–18 min after 0.047–0.063 mg/kg of the S1PR1 inhibitor ponesimod, 33 min after 0.4–0.8 mg/kg of the S1PR1-specific compound TZ82112, and 167–195 min after 1 ng/kg of the immune stimulus endotoxin. Kinetic analysis with metabolite-corrected input function was performed to estimate the free fraction corrected total distribution volume (VT/fP). Whole-body dosimetry scans were acquired in 2 animals (1M, 1F) with a Biograph Vision PET/CT System, and absorbed radiation dose estimates were calculated with OLINDA. Results [18F]TZ4877 exhibited fast kinetics that were described by the reversible 2-tissue compartment model. Baseline [18F]TZ4877 fP was low (< 1%), and [18F]TZ4877 VT/fP values were 233–866 mL/cm3. TZ82112 dose-dependently reduced [18F]TZ4877 VT/fP, while ponesimod and endotoxin exhibited negligible effects on VT/fP, possibly due to scan timing relative to dosing. Dosimetry studies identified the critical organs of gallbladder (0.42 (M) and 0.31 (F) mSv/MBq) for anesthetized nonhuman primate. Conclusions [18F]TZ4877 exhibits reversible kinetic properties, but the low fP value limits quantification with this radiotracer. S1PR1 is a compelling PET imaging target, and these data support pursuing alternative F-18 labeled radiotracers for potential future human studies.

Publisher

Research Square Platform LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3