Some consequences of repeated casting of Co-Cr dental alloy
-
Published:2016
Issue:11
Volume:81
Page:1307-1319
-
ISSN:0352-5139
-
Container-title:Journal of the Serbian Chemical Society
-
language:en
-
Short-container-title:JSCS
Author:
Maksimovic Vesna1,
Stoiljkovic Milovan1ORCID,
Cairovic Aleksandra2
Affiliation:
1. Institute of Nuclear Sciences Vinča, Belgrade
2. School of Dental Medicine, Belgrade
Abstract
The effect of multiple recasting of commercial Co-Cr base dental alloy
(Dentalit-C) on its structural characteristics and ion release rates in
artificial saliva has been investigated. The number of recasting was once,
four and eight times. The as-cast microstructure became more uniform as the
number of recasting was increased whereby macro and microhardness and
electrical conductivity of the castings decreased. Metallic ion release in
artificial saliva was monitored in vitro over the period of 22 weeks at the
temperature of 37 0C and pH 2.3. Only Co and Fe were evidenced in artificial
saliva and their release rates are measured. The ion release rates increases
with time. The ion release rate of Fe was larger than Co. The ion release
rates increases substantially by increasing the number of recasting.
Funder
Ministry of Education, Science and Technological Development of the Republic of Serbia
Publisher
National Library of Serbia
Subject
General Chemistry
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献