Physiological tolerance to uncompensated heat stress in soldiers: Effects of various types of body cooling systems

Author:

Jovanovic Dalibor1,Karkalic Radovan1,Zeba Snjezana2,Pavlovic Miroslav2,Radakovic Sonja3

Affiliation:

1. Technical Testing Centre, Serbian Armed Forces General Staff, Belgrade

2. University of Defence, Medical Faculty of the Military Medical Academy, Belgrade

3. University of Defence, Medical Faculty of the Military Medical Academy, Belgrade + Military Medical Academy, Sector of Preventive Medicine, Belgrade

Abstract

Background/Aim. In military services, emergency situations when soldiers are exposed to a combination of nuclear, biological and chemical (NBC) contamination combined with heat stress, are frequent and complex. In these specific conditions, usage of personal body cooling systems may be effective in reducing heat stress. The present study was conducted in order to evaluate the efficiency of four various types of contemporary personal body cooling systems based on the ?Phase Change Material? (PCM), and its effects on soldiers? subjective comfort and physiological performance during exertional heat stress in hot environments. Methods. Ten male soldiers were voluntarily subjected to exertional heat stress tests (EHSTs) consisted of walking on a treadmill (5.5 km/h) in hot conditions (40?C) in climatic chamber, wearing NBC isolating impermeable protective suits. One of the tests was performed without any additional cooling solution (NOCOOL), and four tests were performed while using different types of cooling systems: three in a form of vests and one as underwear. Physiological strain was determined by the mean skin temperature (Tsk), tympanic temperature (Tty), and heart rate values (HR), while sweat rates (SwR) indicated changes in hydration status. Results. In all the cases EHST induced physiological response manifested through increasing Tty, HR and SwR. Compared to NOCOOL tests, when using cooling vests, Tty and Tsk were significantly lower (on 35th min, for 0.44 ? 0.03 and 0.49 ? 0.05?C, respectively; p < 0.05), as well as the average SwR (0.17 ? 0.03 L/m2/h). When using underwear, the values of given parameters were not significantly different compared to NOCOOL tests. Conclusions. Using a body cooling system based on PCM in the form of vest under NBC protective clothes during physical activity in hot conditions, reduces sweating and alleviates heat stress manifested by increased core and skin temperatures and heart rate values. These effects directly improve heat tolerance, hydration state, decrease in the risk of heat illness, and extends the duration of soldiers? exposure to extreme conditions.

Publisher

National Library of Serbia

Subject

Pharmacology (medical),General Medicine

Cited by 11 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3