Abstract

Introduction/Objective. Transcatheter closure is a well-established procedure for treatment of patent ductus arteriosus (PDA). We aimed to make a comparison between transcatheter PDA occlusion with Flipper coil and Amplatzer Duct Occluder (ADO) and to determine the incidence and significance of procedural complications. Methods. Between November 2004 and October 2014, 148 patients were eligible for transcatheter PDA closure at the University Children?s Hospital in Belgrade, Serbia. The median age was 5.9 years (the range of 0.9 years to 17.3 years) and the median weight was 21 kg (the range of 8.8 kg to 94 kg). Follow-up evaluations with Doppler echocardiogram were performed at one day, three months, and one and two years after the PDA occlusion. Results. Median narrowest PDA diameter was 1.5 mm (the range of 0.5 mm to 5.6 mm). Flipper coil was used for PDA closure in 84 (59.2%) and ADO in 58 patients (40.8%). There was no significant difference in the rate of immediate complete closure between the coil and the ADO group (86.9% vs. 75.9%, p = 0.089), but a significantly higher rate of complete closure was achieved with ADO at one day (83.3% vs. 98.3%, p = 0.004), three months (85.7% vs. 100%, p = 0.002), and both one and two years after the implantation (91.7% vs. 100%, p = 0.041). In total, 12 complications occurred during the procedure, seven of which with coil and five with ADO occlusion of PDA. Conclusion. Transcatheter closure of PDA using both coils and ADOs is a very safe and effective procedure. ADO proved superior to coil in terms of complete closure rate as early as one day after the procedure.

Publisher

National Library of Serbia

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3