Fasciocutaneous flaps of the lower leg: Anatomic study and clinical significance

Author:

Stevanovic Goran1ORCID,Djordjevic Boban2,Dakovic Marija3,Trenkic Srbobran1,Stojiljkovic Danilo1,Jeremic Slavica1,Paravina Jadranka1,Jankovic Irena1ORCID,Golubovic Zoran1,Smiljkovic Igor1

Affiliation:

1. Klinički centar, Klinika za plastičnu i rekonstruktivnu hirurgiju, Niš%SR71-04

2. Vojnomedicinska akademija, Klinika za plastičnu i rekonstruktivnu hirurgiju, Beograd%SR71-02

3. Medicinski fakultet, Institut za anatomiju, Niš%SR13-03.05.12

Abstract

Background/Aim. Soft tissue defects of the lower leg, especially in its distal third, still remain a challenging problem in reconstructive surgery. The aim of this study was to examine septocutaneous system of lower leg vascularization, quantitatively and qualitatively, which is the basis of fasciocutaneous and neurocutaneous flaps. Methods. Septocutaneous systems a. tibialis posterior and a. peroneae were examined by anatomical suprafascial lower leg microdissection of 40 fresh cadavers. Septocutaneous perforators located intermusculary, in deep crural fascia duplicature, were followed from its origin (at main arterial trunks of the lower leg) till the point they reach the deep crural fascia. The number and localization of emergence of the septocutaneous perforators were examined for both above mentioned arterial trunks, and the obtained data were documented by photographs, tables and graphics. Statistical analysis (especially cluster analysis), was used for establishing reliable septocutaneous perforators levels. Results. Septocutaneous perforator systems of the lower leg have constant and reliable pattern of existance. Lower leg length was 36 cm in average, (between 33 and 43 cm). Lower leg was divided in 10 equal segments, 3.6 cm each. A. tibialis posterior and a. peronea had 5 septocutaneous perforators. Cluster analysis of a. tibialis posterior perforators (with diameter ? 0.5 mm), discovered 5 reliable levels of septocutaneous perforators. These levels are at 3.6-10.8 cm; 14.4-21.6 cm and 25.2-28.8 cm. For a. peronea reliable perforators were found at 3.6-10.8 cm, 14.4-18 cm and 21.6-25.2 cm. Posterior tibial artery perforators had the greatest diameter (from 0.5-1.8 mm; mean value 1.14 mm and SD = 0,26 mm). A mean diameter for peroneal artery perforators was 0.9 mm. Conclusion. Existance of reliable levels of septocutaneous perforators of the lower leg enables and makes reconstruction of the soft tissue defects of the lower leg, especially its distal third and foot, much easier.

Publisher

National Library of Serbia

Subject

Pharmacology (medical),General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3