Air staging application effects on overall steam boiler operation

Author:

Stupar Goran1,Tucakovic Dragan1ORCID,Zivanovic Titoslav1,Belosevic Srdjan2,Crnomarkovic Nenad2ORCID

Affiliation:

1. Faculty of Mechanical Engineering, University of Belgrade, Belgrade, Serbia

2. Vinča Institute of Nuclear Sciences, University of Belgrade, Belgrade, Serbia

Abstract

This paper presents the results of calculation system of main processes in power steam boiler, before and after application of air staging. Modified air injection scheme was implemented during 2015 on the power steam boiler within unit 1 of TPP Kostolac B. Measurements performed on site showed that applied reconstruction led to a permanent loss of the steam boiler power. This study was performed in order to define the cause of such an occurrence and to consider the possibility for regaining the designed steam parameters along with keeping NO concentration in prescribed limits. This paper x discusses the influence of repositioning the air injection location on processes within the furnace. Furthermore, the influence of the redistribution of injected air-flow along the furnace height on important boiler operation parameters has been analyzed. Analysis showed that, with appropriate dosing of air along the height of the existing furnace, it is possible to achieve the optimum of the boiler's operation parameters. Results of research showed that air staging throughout the furnace height in best test case additionally reduces NO concentration (195-225 mg/Nm3) and increases the power of x considered boiler (828.8-751.1 MW) with an insignificant decrease of the boiler's efficiency (86.27-86.77%). Furthermore, the designed temperatures of superheated (540-498?C) and reheated (540-518?C) steam have been reached again, whereby the safety of the boiler's operation has been significantly increased. Results of this study improve the present explanation of the processes occurred in the furnace with applied primary measures. They also give directions on defining the most influential parameters on considered processes with the final purpose to increase the efficiency and availability of the entire plant.

Funder

Ministry of Education, Science and Technological Development of the Republic of Serbia

Publisher

National Library of Serbia

Subject

Renewable Energy, Sustainability and the Environment

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3