Experimental study of hydrodynamic parameters regarding on geyser boiling phenomenon in glass thermosyphon using wire-mesh sensor

Author:

Oliveira de1,Ochoski Machado2,Chiarello Conrado1,Nunes Dos1,da Silva1,Dias Dos1,Antonini Alves2

Affiliation:

1. Multiphase Flow Center (NUEM), Federal University of Technology, Parana, Curitiba/PR, Brazil

2. Federal University of Technology - Parana, Ponta Grossa/PR, Brasil

Abstract

The thermosyphon is a type of heat exchanger that has been widely used in many applications. The use of thermosyphons has been intensified in recent years, mainly in the manufacture of solar collectors and various industrial activities. A thermosyphon is a vertical sealed tube filled with a working fluid, consisting of, from bottom to top, by an evaporator, an adiabatic section, and a condenser. The study of geyser-boiling phenomena, which occurs inside the thermosyphon is of extreme importance, therefore the experimental analysis of the parameters related to the two-phase flow (liquid-steam), such as void fraction, bubble frequency, bubble velocity, and bubble length are necessary, since these parameters have a significant influence on heat transfer. In this work, a pair of wire mesh sensors was used, a relative innovative technology to obtain experimental values of the reported quantities for measuring these parameters of slug flow in thermosyphons. An experimental setup is assembled and the sensors are coupled to the thermosyphon enabling the development of the experimental procedure. Here is presented an experimental study of a glass thermosyphon instrumented with two Wire-Mesh Sensors, in which the aforementioned slug flow hydrodynamic parameters inherent to the geyser type boiling process are measured. It was measured successfully, as a function of the heat load (110, 120, 130, 140, and 150W), the void fraction (instantly and average), liquid film thickness, translation velocity of the elongated bubbles, lengths of the bubbles, and the liquid slug (displaced by the bubble rise up). It was observed that the higher the heat load, the lower is the bubble translation velocity. For all heat loads, based on the measured length of liquid slug (consequent displacement of liquid volume), caused by bubbles rise from evaporator to condenser, it could be affirmed to some extent that both boiling regime (pool and film) exist in the evaporator. The measured average void fraction (80%) and liquid film thickness (around 2.5mm) during the elongated bubble passages were approximately constant and independent of the heat load.

Publisher

National Library of Serbia

Subject

Renewable Energy, Sustainability and the Environment

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3