Dose non-linearity of the dosimetry system and possible monitor unit errors on medical linear accelerators used in conventional and intensity-modulated radiation therapy

Author:

Muhammad Wazir1,Hoon Lee2,Alam Khan3,Maqbool Muhammad4,Khan Gulzar5

Affiliation:

1. Department of Physics, Kyungpook National University, Daegu, Republic of Korea + Department of Medical Physics, Institute of Nuclear Medicine Oncology and Radiotherapy (INOR), Abbottabad, Pakistan

2. School of Energy Engineering, Kyungpook National University, Daegu, Republic of Korea

3. Institute of Physics and Electronics, University of Peshawar, Khyber Pakhtunkhwa, Pakistan

4. Department of Physics and Astronomy, Ball State University, Muncie, Ind., USA

5. Department of Physics, Kyungpook National University, Daegu, Republic of Korea

Abstract

The purpose of this work is to study dose non-linearity in medical linear accelerators used in conventional radiotherapy and intensity-modulated radiation therapy. Open fields, as well as the enhanced dynamic wedge ones, were used to collect data for 6 MV and 15 MV photon beams obtained from the VARIAN linear accelerator. Beam stability was checked and confirmed for different dose rates, energies, and application of enhanced dynamic wedge by calculating the charge per monitor unit. Monitor unit error was calculated by the two-exposure method for open and enhanced dynamic wedge beams of 6 MV and 15 MV photons. A significant monitor unit error with maximum values of ?2.05931 monitor unit and ?2.44787 monitor unit for open and enhanced dynamic wedge beams, respectively, both energy and dose rate dependent, was observed both in the open photon beam and enhanced dynamic wedge fields. However, it exhibited certain irregular patterns at enhanced dynamic wedge angles. Dose monitor unit error exists only because of the overshoot phenomena and electronic delay in dose coincident and integrated circuits with a dependency on the dose rate and photon energy. Monitor unit errors are independent of the application of enhanced dynamic wedge. The existence of monitor unit error demands that the dose non-linearity of the linear accelerator dosimetry system be periodically tested, so as to avoid significant dosimetric errors.

Publisher

National Library of Serbia

Subject

Safety, Risk, Reliability and Quality,Nuclear Energy and Engineering

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3