Effects of the light tip position on the degree of conversion and dentin bond strength of a universal adhesive

Author:

Komlenic Vojislav1,Miletic Vesna1ORCID

Affiliation:

1. University of Belgrade, School of Dental Medicine, DentalNet Research Group, Belgrade, Serbia

Abstract

Introduction/Objectives. To measure the degree of conversion (DC), immediate and long-term microshear bond strength (?SBS) to dentin of a universal adhesive relative to the light tip position and adhesive application protocol. Methods. Mid-coronal flat dentin of 48 human third molars was exposed and split in halves. Single Bond Universal (SBU; 3M) adhesive was applied to each half following ?total-etch? (TE) or ?self-etch? (SE) approach. Depending on the light tip (Bluephase G2, Ivoclar Vivadent, Schaan, Liechtenstein) angle and distance from adhesive surface, three groups were compared: ?1 mm_90?? (control); ?8 mm_90?? and ?8 mm_60??. Cylindrical composite build-ups (o1.7mm, Filtek Z250, 3M) were prepared in each half. DC was measured using Raman spectroscopy. ?SBS was measured after 24 hours and six months storage in distilled water at 37?C. Fracture types were analyzed. Results. No significant difference in DC was detected between groups ?1 mm_90?? (89.1 ? 6.2%) and ?8 mm_90?? (94.6 ? 1.2%) (p > 0.05), both showing significantly higher DC (p < 0.05) than ?8 mm_60?? group (74.9 ? 9.5%) (p < 0.05). Initially, there were no significant differences in ?SBS between groups (p > 0.05). Group ?1 mm_90?? TE (12.8 ? 4.3 MPa) and group ?8 mm_60?? TE (14.7 ? 5.7 MPa) showed significantly lower ?SBS after aging (8.4 ? 4.3 MPa and 9.2 ? 2.6 MPa, respectively) (p < 0.05). Adhesive fractures were predomintantly detected. Conclusion. Initially, both application protocols resulted in similar bond strength to dentin of a universal adhesive in suboptimal curing conditions. In the long-term, SE showed greater adhesive resistance to degradation resulting in smaller decrease in bond strength compared to TE. Light tip angulation affected DC and ?SBS more than tip-to-surface distance.

Funder

Ministry of Education, Science and Technological Development of the Republic of Serbia

Publisher

National Library of Serbia

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3