Abstract
The performance of Scheffler reflector has been studied. In this system
storage reservoir was installed at Focus point. It has a single large
diameter drum which serves the dual purpose of absorber tube and storage
tank. The drum is sized to have a storage capacity of 20 liter for
experiment. The tests were carried out with this set up and were repeated for
several days. Performance analysis of the collector has revealed that the
average power and efficiency in terms of water boiling test to be 1.30
kilowatts and 21.61 % respectively against an average value of beam
radiations of 742[Wm-2]. The maximum water temperature in the storage tank of
98?C has been achieved on a clear day operation and ambient temperature
between 28?C to 31?C.