Joggle lap shear testing of deep occlusal composite restorations lined with Dycal, Dycal LC, conventional or resin-modified glass ionomer

Author:

Stojanovska Vera1,Ivanoff Chris2,Muratovska Ilijana1,Popovska Lidija1,Garcia-Godoy Franklin2,Hottel Timothy3,Markovic Dejan4ORCID,Morrow Brian2

Affiliation:

1. Sts. Cyril and Methodius University, Department of Cariology and Endodontics, Faculty of Dentistry, Department of Cariology and Endodontics, Skopje, Macedonia

2. University of Tennessee, College of Dentistry, Department of Bioscience Research, Memphis, USA

3. University of Tennessee, College of Dentistry, Department of Prosthodontics, Memphis, USA

4. Faculty of Dental Medicine, Department of Paediatric and Preventive Dentistry, Belgrade

Abstract

Background/Aim. The longevity of a dental restoration may be predicted to some degree by its adhesive ability, and this, in turn, can be measured by bond strength testing between restorative materials and tooth structure. The aim of this study was to test an innovative joggle lap shearing jig that integrates the tooth and the entire biomechanical unit into testing, to compare the shear bond strengths of Class I occlusal composite restorations in deep cavity preparations lined with Dycal, Dycal LC, conventional glass ionomer or resin-modified glass ionomer. The mode of failure (adhesive, cohesive, mixed) after debonding was determined by stereomicroscopy. Methods. A total of 150 standardized occlusal cavities were prepared and divided into five groups. The group I cavities (n = 30) were coated with adhesive (ExciTE?F) and filled directly with composite (TetricEvoCeram). The group II and III cavities were lined with Dycal (n = 30) or Dycal LC (n = 30) before placing composite. The groups IV and V specimens were based with Fuji IX (n = 30) or Fuji II LC (n = 30). Shear bond strengths were determined with a universal testing machine and fractured bonding sites were analyzed under stereomicroscope. The mean bond strengths were analyzed using one-way ANOVA test (p < 0.05) and the means between the groups were analyzed with Student?s t-test. Results. The shear bond strength (MPa) of composite restorations in cavities without base (23.91 ? 4.54) was higher than cavities lined with Fuji II LC (17.45 ? 2.74), Fuji IX (8.76 ? 2.57), Dycal LC (13.07 ? 1.84) or Dycal (6.12 ? 1.28). The results using the jogged lap shearing jig were consistent with the literature. Conclusion. The shear bond strength of occlusal composite restorations in deep cavities without liners was greater than cavities lined with Fuji II LC > Fuji IX > Dycal LC > Dycal.

Publisher

National Library of Serbia

Subject

Pharmacology (medical),General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司