Accuracy of ultrasonic fetal weight estimation using head and abdominal circumference and femur length

Author:

Mladenovic-Segedi Ljiljana1,Segedi Dimitrije1

Affiliation:

1. Klinika za ginekologiju i akušerstvo, Klinički centar 'Novi Sad', Novi Sad

Abstract

Introduction Former investigations have shown that the accuracy of fetal weight estimation is significantly higher if several ultrasonic fe?tal parameters are measured, because the total body mass depends on the size of fetal head, abdominal circumference and femur length. The aim of this investigation was to establish the best regression model, that is a number of combinations of fetal parameters providing the most accurate fetal weight estimation in utero in our population. Material and methods This prospective study was carried out at the Gynecology and Obstetrics Clinic of the Clinical Center Novi Sad. It included 270 pregnant women with singleton pregnancies within 72 hours of delivery who underwent ultrasound measurements of the biparietal diameter (BPD), head circumference (HC), ab?dominal circumference (AC) and femur length (FL). Results In regard to fetal weight estimation formulas, the deviation was lowest using regression models that simultaneously analyzed four fetal parameters (0.55%) with SD ?7.61%. In these models the estimates of fetal weights were within ?5% of actual birth weight in 48.89%, and within ?10% of actual birth weight in 81.48%. Good results were also obtained using AC, FL measurements (0.92% ? 8.20) as well as using AC, HC, FL measurements (-1.45% ? 7.81). In our sample the combination of AC and FL model gave better results in fetal weight estimation (0.92 ? 8.20%) than the one using BPD and AC (2.97 ? 8.83%). Furthermore, the model using parameters AC, HC and FL showed a lower error in accuracy (-1.45 ? 7.81%) than the model using BPD, AC and FL (2.51 ? 7.82%). Conclusion This investigation has confirmed that the accuracy of fetal weight estimation increases with the number of measured ultra?sonic fetal parameters. In our population the greatest accuracy was obtained using BPD, HC, AC and FL model. In cases when fast estimation of fetal weight is needed, AC, HC, FL model may be appropriate, but if fetal head circumference cannot be measured (amnion rupture and/or fetal head already in the pelvis) the AC, FL model should be used.

Publisher

National Library of Serbia

Subject

General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3