Affiliation:
1. Department of Radiation and Environmental Protection, Vinča Institute of Nuclear Sciences, National Institute of the Republic of Serbia, University of Belgrade, Belgrade, Serbia
2. Radiation Chemistry and Dosimetry Laboratory, Ruđer Bošković Institute, Zagreb, Croatia
Abstract
Passive solid state dosimeters, such as thermoluminescence dosimeters,
provide integrated measurement of the total dose and are widely used in
environmental monitoring programs. The objective of this paper
is to provide a comprehensive review on the use of thermoluminescent dosimetry methods for monitoring radiation dose in the environment. The
article presents the part of the research results of the project PREPAREDNESS (EMPIR 2016 call for Metrology for Environment joint research project)
with a particular objective to harmonize procedures used by
dosimetry services, relevant authorities and Institutes across the Europe. To
achieve this, different monitoring routines that are based on passive environ
mental dosimetry methods are investigated. Differences in performing
specific steps such as preheating, reading, annealing, minimizing fading, and others, are analyzed. The investigation was performed by
means of qualitative literature review that showed the lack of information about specific steps. The conclusion of this work is that
thermoluminescent dosimetry measurement system has to be type-tested
even though the testing procedure is complicated. In addition to this,
control dosimeters should be introduced, International Organization
for Standardization protocols should be followed during calibration, and
finally, parameters influencing the measurement uncertainty have to be
identified and well understood in order to pro duce ac cu rate dose measurement results.
Publisher
National Library of Serbia
Subject
Safety, Risk, Reliability and Quality,Nuclear Energy and Engineering
Cited by
7 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献