Multidetector computed tomography (MDCT) estimation of prevalence and anatomic characteristics of the sternal body foramen in the population of central Serbia

Author:

Vulovic Maja1ORCID,Zivanovic-Macuzic Ivana1ORCID,Jeremic Dejan1ORCID,Djonovic Nela2ORCID,Radunovic Aleksandar3,Jovanovic Milan4,Milosevic Bojan5ORCID,Aleksic Zoran6,Stankovic Ivana7,Vojinovic Radisa8

Affiliation:

1. Faculty of Medical Sciences, Department of Anatomy, Kragujevac + University of Defence, Faculty of Medicine of the Military Medical Academy, Belgrade

2. Faculty of Medical Sciences, Department of Hygiene and Ecology, Kragujevac

3. Military Medical Academy, Clinic for Orthopedic Surgery, Belgrade

4. University of Defence, Faculty of Medicine of the Military Medical Academy, Belgrade

5. Faculty of Medical Sciences, Department of Surgery, Kragujevac

6. University Clinical Center of Republic of Srpska, Clinic for General and Abdominal Surgery, Bosnia and Herzegovina

7. Ambulance Brigade of Guards, Belgrade

8. Faculty of Medical Sciences, Department of Radiology, Kragujevac

Abstract

Background/Aim. The most frequent form of sternal defects is a single foramen, usually located at the distal half of the sternal body, with prevalence that varies among different ethnic populations. Clinical importance of these defects arises from various diagnostic and therapeutic sternal treatments and close location of heart, lungs and other vital organs of the chest cavity. The aim of this study was to determine the prevalence and morphometric characteristics of the sternal midline foramen in the population of central Serbia. Methods. The multidetector computed tomography (MDCT) chest images of 422 patients of both genders were analyzed. The radiological imaging was performed on 64- slice MDCT scanner (Aquilion 64, Toshiba, Japan). All scans were performed in the axial plane, with subsequent multiplanar reconstruction (MPR). Due to the angulation of the sternal body coronal curved-planar, the images were obtained in order to show the whole length of the sternum and the vertical diameter of the sternal foramen. The measurements were done using the commercially available software (Imaging Software ver. 4.1.14.0, Vital-Images). Results. The solitary foramen, located in the distal segment of the sternal body, was detected in 24 patients, representing 5.9% of the observed population with slightly higher prevalence in males. The average size of foramen was 3.9 ? 4.2 mm. The mean distance from the skin was 12.7 ? 3.3 mm, the distance from skin to pericardium was on average 37.3 ? 8.2 mm, while the average distance from skin to pleura was 25 ? 5.9 mm. The average depth of foramen 8.7 ? 2 mm, while the mean distance from the posterior surface of foramen to pericardium was 12.7 ? 9.1 mm. Conclusion. The results presented in this paper confirmed the prevalence of 5.9% regarding the midline sternal foramen in the observed population. Serious complications of the sternal puncture could be prevented by prior MDCT imaging.

Publisher

National Library of Serbia

Subject

Pharmacology (medical),General Medicine

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3