Radiation safety aspects of 90Y bremsstrahlung radiation produced from radiation shielding apparatus using the Monte Carlo simulation

Author:

Jumpee Chayanit1,Onnomdee Chanakarn2,Charoenphun Putthiporn3,Phruksarojanakun Phiphat4,Chuamsaamarkkee Krisanat3

Affiliation:

1. Department of Radiologic Technology, Faculty of Associated Medical Science, Chiangmai University, Chiangmai, Thailand

2. Master of Science Program in Medical Physics, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, Thailand

3. Master of Science Program in Medical Physics, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, Thailand + Department of Diagnostic and Therapeutic Radiology, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, Thailand

4. Office of Atoms for Peace, Ministry of Higher Education, Science, Research and Innovation, Bangkok, Thailand

Abstract

Selective internal radiation therapy using an 90Y labelled microsphere is increasingly used to treat hepatocellular carcinoma. Based on its properties, 90Y can produce bremsstrahlung radiation which is essential for post-treatment localisation and dosimetry. However, bremsstrahlung radiation could lead to an increase of radiation exposure of radiation workers. The aim of this work was to determine the 90Y bremsstrahlung radiation produced from the polymethyl methacrylate radiation shielding apparatus using the Monte Carlo simulation. A scintillation detector with a 137Cs standard source was used to validate the Monte Carlo simulation. After validation, the 90Y bremsstrahlung photons spectrum produced from the radiation shielding apparatus was simulated. The radiation equivalent dose rates to the head, neck, body, lower extremities at a distance of 30 centimeters, and finger (contact with the knob) were estimated to be 4.9 ? 0.6, 6.2 ? 0.1, 18.9 ? 0.4, 13.1 ? 0.6, and 3900 ? 50 ?Svh?1, respectively. The corresponding annual doses exceeded the limit when radiation workers performed 2631, 1563, 769, and 515 cases per year with contact the knob 3, 5, 10, and 15 minutes per case, respectively. The simulation result showed that radiation exposure of radiation workers and the number of selective internal radiation therapy procedures performed should be considered.

Publisher

National Library of Serbia

Subject

Safety, Risk, Reliability and Quality,Nuclear Energy and Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3