Individual and simultaneous determinations of phenothiazine drugs using PCR, PLS and (OSC)-PLS multivariate calibration methods

Author:

Karimi Mohammad1,Ardakani Mazloum2,Behjatmanesh-Ardakani Reza3,Nezhad Hormozi4,Amiryan Hamzeh3

Affiliation:

1. Department of Chemistry, Payame Noor University of Sirjan, Sirjan, Iran + Department of Chemistry, Payame Noor University of Ardakan, Ardakan, Iran + Department of Chemistry, Shahid Bahonar University of Kerman, Kerman, Iran

2. Department of Chemistry, Yazd University, Yazd, Iran

3. Department of Chemistry, Payame Noor University of Ardakan, Ardakan, Iran

4. Department of Chemistry, Persian Gulf University, Bushehr, Iran

Abstract

Individual and simultaneous determinations of some phenothiazine drugs are described. The individual determination method is based on the reaction of chlorpromazine hydrochloride (CPH), promethazine hydrochloride (PH), trifluoperazine hydrochloride (TFPH), trimipramine maleate (TPM) and thioridazine hydrochloride (TRDH) with complex of [Fe(Bpy)3]3+. In the presence of phenothiazine derivatives, [Fe(Bpy)3]3+ is reduced easily to the colored complex [Fe(Bpy)3]2+, which shows an absorption maximum at 525 nm. The individual method is highly sensitive and suitable for 0.3-190 ?g ml-1 concentrations, with detection limits in the range 0.18-2.46 ?g ml-1. Simultaneous kinetic-spectrophotometric determination of ternary mixture of CPH, PH and TPM using principal component regression (PCR), partial least squares (PLS) and orthogonal signal correction (OSC)-PLS multivariate calibration methods is also described. The simultaneous methods are based on the difference observed in the reduction rate of the [Fe(Bpy)3]3+ complex with CPH, PH and TPM in acidic media. The results showed that the simultaneous determination of CPH, PH and TPM can be performed in the concentration ranges of 0.5-120.0, 0.3-80.0 and 5.0-100.0 ?g ml-1, respectively, for three methods (PCR, PLS and OSC-PLS). The root mean square errors of prediction (RMSEP) of CPH, PH and TPM were 0.346, 0.663 and 0.820 (for PCR) 0.317, 0.659 and 0.830 (for PLS) and 0.087, 0.124 and 0.085 (for OSC-PLS), respectively. The proposed methods were successfully applied to the individual and simultaneous determination of phenothiazine derivatives in pharmaceutical preparations, the results of which compared well with those obtained by the official method, and several synthetic (spiked) samples, whereby satisfactory results were obtained.

Publisher

National Library of Serbia

Subject

General Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3