Affiliation:
1. University of Defence, NBC Defence Institute, Vyskov, Czech Republic
Abstract
The manuscript clarifies the issues concerning the effective miniaturization
of readout of the plastic scintillators while maintaining their high
detection efficiency and sensitivity. Values obtained from the measurements
of the chosen gamma emitters (60Co, 137Cs, 241Am), at various distances,
were used to compare the detection efficiencies. The organic plastic
scintillators, with the ternary system of different shapes and volumes,
were chosen for the measurement. The detection parameters for the examined
1" PMT, with variable photocathode geometry, were experimentally found and
compared to the normally used 2" PMT, with the circular type of
photocathode. The primary aim of this work was to verify whether, in the
case of mobile applications, such as UAV, it is possible to replace the
currently bulky and quite heavy electronics with a miniature version and
simultaneously preserve their detection parameters.
Publisher
National Library of Serbia
Subject
Safety, Risk, Reliability and Quality,Nuclear Energy and Engineering
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献