Lung ultrasound for volume status assessment in chronic hemodialysis patients

Author:

Ivanov Igor1,Veselinov Vladimir2,Celic Dejan3,Dejanovic Jadranka1,Obradovic Dusanka4ORCID,Knezevic Violeta3

Affiliation:

1. Institute for Cardiovascular Diseases of Vojvodina, Sremska Kamenica, Serbia + University of Novi Sad, Faculty of Medicine, Novi Sad, Serbia

2. General Hospital Kikinda, Kikinda, Serbia

3. University of Novi Sad, Faculty of Medicine, Novi Sad, Serbia + Clinical Center of Vojvodina, Clinic for Nephorlogy and Clinic Immunology, Novi Sad, Serbia

4. University of Novi Sad, Faculty of Medicine, Novi Sad, Serbia + Institute for Lung Disease of Vojvodina, Sremska Kamenica, Serbia

Abstract

Backoground/Aim. Assessing volume status in chronic hemodialysis (HD) patients is difficult despite several techniques have been developed. The aim of this study was to demonstrate the adequacy and efficacy of lung ultrasound (LUS) and B line score (BLS) in the assessment of volume status in patients on HD in comparison to other techniques: ultrasonographic determination of inferior vena cava diameter (IVCD), echocardiography (ECHO) and B-type natriuretic peptide (BNP) determination. Methods. LUS, ECHO, ultrasonography of inferior vena cava in inspiration (IVCDi) and expiration (IVCDe), and BNP sampling were performed before and after HD in 83 patients. Results. A significant reduction of BLS, IVCDi, IVCDe, BNP and several ECHO parameters such as left atrium diameter (LA), left ventricular internal dimension in diastole and systole (LVIDd and LVIDs, respectively), and left atrial volume in systole (LAVs), was registered (p < 0.001). There was a significant correlation between BLS and BNP before (p = 0.01) and after HD (p = 0.05), and a weaker but significant correlation between BLS and IVCDi and IVCDe before HD (p = 0.05). Conclusion. All techniques assessed hypervolemia before and after HD successfully. BNP correlated with LUS before and after HD, and IVCDi and IVCDe correlated with LUS only before HD. LUS is cheap and simple to perform, can be performed bedside and can be reliably used for assessing volume status in HD patients.

Publisher

National Library of Serbia

Subject

Pharmacology (medical),General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3