Affiliation:
1. School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore, Singapore
Abstract
A mock handset with heat storage unit (HSU) has been designed, fabricated,
and experimented under various conditions to examine the effect of external
heat sink on the handset?s transient temperature distribution, performance of
the individual HSU under different power level and orientation, as well as
under the more realistic cyclic heating. The cooling of the handset is
through using a phase change material (PCM), n-eicosane, stored in the
external HSU connected to the handset through a miniature heat pipe. The heat
pipe channels the internal heat dissipation to the HSU where it is absorbed
by the PCM. Results show that the temperature is significantly lowered with
the PCM-based HSU.
Publisher
National Library of Serbia
Subject
Renewable Energy, Sustainability and the Environment
Cited by
6 articles.
订阅此论文施引文献