Correlation of sera concentra tions of thyroperoxidase a utoantibodies measured by two radioimmunoassays

Author:

Vrndic Olgica1,Zivancevic-Simonovic Snezana1ORCID,Dimitrijevic Ljiljana2,Djukic Aleksandar1,Arsenijevic Nebojsa1ORCID

Affiliation:

1. Medicinski fakultet, Kragujevac

2. Institut za imunologiju i virusologiju 'Torlak', Beograd

Abstract

Introduction. Thyroid peroxidase-specific autoantibodies (TPO Abs) are mostly measured in patients with autoimmune thyroid diseases. The aim of this study was to compare TPO Ab concentrations measured by two radioimmunoassays. Material and methods. Our investigation included 38 patients. Sera concentrations of TPO Abs were measured by using Cis biointernational (France) and Immunotech (Czech Republic) assays. Results. Concentrations obtained by two assays were extensively different. The values measured by Cis biointernational assay were higher than ones obtained by Immunotech assay. The statistical arrangement of results showed the direct correlation between the two assays, with the coefficient of agreement R=0.6239 (p<0.001). The analysis of relative values (ratio of measured and upper limit values given by the manufacturer) demonstrated the statistically significant difference (p=0.003) between values measured by Cis biointernational (18.94?37.22) and by Immunotech assay (4.22?8.22) concerning the distinction between normal and raised concentrations of TPO Abs. The agreement of results (enhanced or normal TPO Ab concentrations in both tests) was shown in 30 sera samples (78.95%), but in residual 8 sera (21.05%) normal TPO Ab concentrations were obtained by Immunotech, and enchanced by Cis biointernational assay. There is no difference in capability of distinction between normal and pathological results between the two tests (?2=3.484, p>0.05). The highest concentration of TPO Ab measured by Cis biointernational assay was not the highest one in Immunotech assay, which might be a reflection of different specificity of antibodies used in two diagnostic tests. Conclusion. TPO Ab concentrations obtained by Cis biointernational and Immunotech assays are very different. In several sera samples, normal concentrations of TPO autoantibodies were obtained by Immunotech assay and enhanced by Cis biointernational assay. The highest value obtained by one is not the highest value measured by another assay we used.

Publisher

National Library of Serbia

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3