Affiliation:
1. Yellow River Conservancy Technical Institute, Kaifeng, Henan, China
Abstract
In order to improve the thermal power dissipation of batteries and reduce the
maximum temperature difference of batteries, the air conditioning system
using battery type was optimized. Using multi-objective optimization method
based on orthogonal experiment and multiple rotations, the local optimum
values of multi-objective were obtained: the left end height A of entrance
area and the height B of air outlet were 9 mm and 28 mm, respectively, with
a tolerance value C of 0.4 mm for battery spacing. The simulation results of
this optimization model show that the maximum temperature difference of the
battery volume is 306.627 K (33.477?C) and 3.815 K (3.815?C), respectively.
Compared with the initial model, they are reduced by 9.55% and 25.89%,
respectively. Compared with the single factor analysis optimization model,
they are reduced by 0.36% and 20.27%, respectively, indicating that the
multi-objective optimization results are better. This multi-objective
programming solves the problem of different parameters of air conditioning
heat dissipation model to some extent, and can provide reference for the
optimization design of other models.
Publisher
National Library of Serbia
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献