Affiliation:
1. Department of Chemistry, Science and Research Branch, Islamic Azad University, Tehran, Iran
Abstract
The simultaneous determination of sulfamethoxazole (SMX) and trimethoprim
(TMP) mixtures in bovine milk by spectrophotometric method is a difficult
problem in analytical chemistry, due to spectral interferences. By means of
multivariate calibration methods, such as partial least square (PLS)
regression, it is possible to obtain a model adjusted to the concentration
values of the mixtures used in the calibration range. Genetic algorithm (GA)
is a suitable method for selecting wavelengths for PLS calibration of
mixtures with almost identical spectra without loss of prediction capacity
using the spectrophotometric method. In this study, the calibration model
based on absorption spectra in the 200-400 nm range for 25 different mixtures
of SMX and TMP Calibration matrices were formed form samples containing
0.25-20 and 0.3-21 ?g mL-1 for SMX and TMP, at pH=10, respectively. The root
mean squared error of deviation (RMSED) for SMX and TMP with PLS and genetic
algorithm partial least square (GAPLS) were 0.242, 0.066 ?gmL-1 and 0.074,
0.027 ?g mL-1, respectively. This procedure was allowed the simultaneous
determination of SMX and TMP in synthetic and real samples and good
reliability of the determination was proved.
Publisher
National Library of Serbia
Cited by
10 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献