Affiliation:
1. Warsaw University of Technology, Institute of Heat Engineering, Warsaw, Poland
Abstract
The steam condenser is one of the most important element in whole power plant
installation. Their proper design and operation makes a significant
contribution to the efficiency of electricity production. The purpose of this
article is to propose a two-dimensional mathematical model that allows
modeling condenser work. In the model, the tube bundle is treated as a porous
bed. The analysis has been subjected to a two passes power condenser with a
capacity of 50 MW. The mathematical analysis was compared with the results of
experimental studies. The average error between the model and the experiment
for difference of cooling water temperatures was 5.15% and 11.60% for the
first and second pass respectively. This allows to conclude that the proposed
model is good enough to optimize future work of the condenser.
Publisher
National Library of Serbia
Subject
Renewable Energy, Sustainability and the Environment
Cited by
20 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献