Cone beam computed tomography analysis of maxillary vestibular bone thickness in the esthetic region

Author:

Djurdjevic Milica1,Bubalo Marija2,Lukovic Ana3ORCID,Igic Ana4,Acovic Aleksandar1ORCID,Kanjevac Tatjana5ORCID

Affiliation:

1. University of Kragujevac, Faculty of Medical Sciences, Department of Dentistry, Kragujevac, Serbia

2. Military Medical Academy, Dental Clinic, Belgrade, Serbia + University of Defence, Faculty of Medicine of the Medical Military Academy, Belgrade, Serbia

3. University of Kragujevac, Faculty of Medical Sciences, Department of Surgery, Kragujevac, Serbia

4. University of Niš, Faculty of Medicine, Preventive and Pediatric Dentistry, Niš, Serbia

5. Institute of Dentistry, Kragujevac, Serbia

Abstract

Background/Aim. Insufficient buccal bone thickness (thickness less than 2 mm) frequently leads to fenestration and dehiscence, and their consequences are additional bone resorption. That represents an additional problem during implant placement. Cone beam computed tomography (CBCT) is becoming a priority in the diagnosis of bone thickness needed for implant placement since it has proven to be an accurate and largely reliable diagnostic tool in the image of morphology and buccal wall thickness. The aim of this study was to measure the vestibular bone thickness of the anterior maxillary region in the Serbian population and compare the difference between men and women, as well as between the left and right sides of the jaw. Methods. CBCT images of 68 patients were examined from the existing database. The length from the cementoenamel junction to the beginning of the alveolar bone was measured, followed by the thickness of the vestibular bone at various clinically relevant locations. The data were statistically processed and analyzed. Results. A total of 373 teeth of the frontal region of the upper jaw, including 128 central incisors, 124 lateral incisors, and 121 canines, were analyzed. The thickness of the buccal bone in more than 88% of cases was less than 1.5 mm at all reference points, with mean values from 0.72 to 1.02 mm. Conclusion. A very small number of maxillary teeth have a vestibular bone thickness greater than 2 mm; therefore, the criterion to provide at least 2 mm of thickness needed for implant placement is difficult to meet. That increases the use of auxiliary methods of bone augmentation during immediate implant placement.

Publisher

National Library of Serbia

Subject

Pharmacology (medical)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3