Abstract
In this paper, a real microwave applicator with a wave guide used to launch the energy from the source into the cavity is analyzed using 3D TLM method. In order to investigate the influence of the positions and number of feed wave guides to the number of the resonant modes inside the cavity, obtained results are compared with analytical results and results obtained by using TLM software with an impulse excitation as well. TLM method is applied to the both empty and loaded rectangular metallic cavity, and a very good agreement between simulated and experimental results is achieved.