Dosimetric comparison of two-dimensional versus three-dimensional intracavitary brachytherapy in locally advanced cervical cancer

Author:

Klisarovska Violeta1,Smichkoska Snezhana2,Chakalaroski Petar1,Krstevska Valentina3,Dimitrovska Nadica4,Stefanovski Zoran4,Lazarova Emilija2

Affiliation:

1. University Clinic of Radiotherapy and Oncology, Department of Gynecologic Oncology and Brachytherapy, Skopje, FYR Macedonia

2. University Clinic of Radiotherapy and Oncology, Department of Breast Cancer, Skopje, FYR Macedonia

3. University Clinic of Radiotherapy and Oncology, Department of Head and Neck Cancer, Skopje, FYR Macedonia

4. University Clinic of Radiotherapy and Oncology, Medical Faculty, Department of Medical Radiation Physics, Skopje, FYR Macedonia

Abstract

Introduction/Objective. The aim of this study was to dosimetric comparison of two-dimensional (2D) with three-dimensional (3D) planning for high-dose-rate intracavitary brachytherapy (HDR-BT) in locally advanced cervical cancer by dose evaluation in given International Commission on Radiation Units and Measurements (ICRU) reference points, as well as in target volume and organs at risk (OAR). Methods. 66 sessions of HDR-BT were performed in 22 patients, with 3D planning, but also virtual 2D plan for dosimetric comparison was made. 2D planning was performed on radiography obtained by C-arm in ICRU points, while 3D planning in volumes delineated on computer tomography. Results. The comparative analysis has indicated a significant mean dose difference of point ?A? left (p=0.00014) and right (p=0.003), through higher doses in 2D and lower doses in 3D reconstructed points "A". According to the dose volume histograms 56.88% and 61.41% mean target volume received 100% and 90% of prescribed dose, respectively. 2D bladder analysis showed a mean dose of 3.487 Gy in ICRU point, while in 3D analysis a maximum mean dose of 8.804 Gy and mean dose of 4.716 Gy in 2ccm volume. 2D analysis showed rectal mean dose of 2.892 Gy in ICRU points, while 3D analysis maximum mean dose of 6.411 Gy and 3.947 Gy mean dose in 2ccm volume. Conclusion. 2D planning showed unreal higher doses in the ICRU points for the target and lower doses for the OAR.

Publisher

National Library of Serbia

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3