Affiliation:
1. Ovidius University of Constanța, Romania
Abstract
This article presents the results of the study of the heat transfer in a heat ex-changer where the working fluid is the crude oil prepared for desalination, and the thermic agent is the re-circulating heavy gasoline fraction. Firstly, the Reynolds numbers have been computed using the temperatures and flow rates of the fluids as input variables. Then, general regression neural network and multi-layer perceptron were used for the outlet temperatures estimation using the inlet temperatures and the Reynolds numbers as input variables. The best models on the training dataset were obtained utilizing a multilayer perceptron with one hidden layer, while the best performance on the validation dataset was obtained using a multilayer perceptron network with two hidden layers.
Publisher
National Library of Serbia
Subject
Renewable Energy, Sustainability and the Environment
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献