Abstract
In order to solve the shortcomings of single air source heat pump, single
solar heat pump and solar air double heat source heat pump, one solar
electric heat pump and multi-stage solar heat pump dual source heat pump, a
solar integrated heat source heat pump is designed. The heating capacity and
COP of the same heat pump and the solar double heat pump under three
different operating conditions were simulated, and the simulation results
were compared and analyzed. The simulation results were analyzed. The
results show that the heat capacity and COP of the solar double heat pump
system are higher than those of the heat pump system. With the continuous
decrease of outdoor temperature, the advantages of solar wind tunnel hybrid
heat pump system are more obvious.