New concept of in/out air quality control in livestock buildings
-
Published:2022
Issue:6 Part A
Volume:26
Page:4819-4829
-
ISSN:0354-9836
-
Container-title:Thermal Science
-
language:en
-
Short-container-title:THERM SCI
Author:
Ivanisevic Mladen1ORCID, Zoranovic Miodrag1, Topisirovic Goran2ORCID, Jugovic Milan3ORCID, Rajs Vladimir4ORCID, Vejnovic Srdjan1, Keselj Krstan1ORCID
Affiliation:
1. University of Novi Sad, Faculty of Agriculture, Novi Sad, Serbia 2. University of Belgrade, Faculty of Agriculture, Belgrade - Zemun, Serbia 3. University of East Sarajevo, Faculty of Agriculture, East Sarajevo, Bosnia and Herzegovina 4. University of Novi Sad, Faculty of Technical Sciences, Dositeja Obradovića, Novi Sad, Serbia
Abstract
The object of this research is the new concept of the original universal system for air quality and energy control in laboratory conditions (wet scrubbing system) based on the ?clean air in/out? principle. Namely, the process involves a partial or complete exchange of recirculated treated air. From the aspect of water, as a pure medium, the system is characterized by broad application in the open, semi-open, and closed air treatment systems: primarily in the breeding and accompanying agricultural facilities, industrial, cultural, sports, tourist, medical and other controlled spaces. The analysis showed that the system at its inlet unit and with the block structure and logical phase development, proved energy, environ-mental and qualitative efficiency in the removal of PM10 and PM2.5 particles from the controlled dust doses in laboratory air. The measurements of PM10 and PM2.5 concentrations were performed with two Alphasense OPC-N3 optical counters at the inlet and outlet of the system. Five operating regimes with frequency regulated number of revolutions of the turbo elements that was taken as an independent variable, achieved different degrees of removal of PM10 and PM2.5 from the treated laboratory air: 97.70-98.53% and 62.19-75.75%, respectively. The assessment of system energy use was done by parallel measuring of electric power and comparative deviations of its absolute values in the first decimal. Energy consumption for the treatment of 1m3 of air ranged from 0.00011- 0.00016 kWm?3. Statistical analysis of qualitative indicators revealed significant differences between the operating regimes and the obtained values.
Funder
Ministry of Education, Science and Technological Development of the Republic of Serbia
Publisher
National Library of Serbia
Subject
Renewable Energy, Sustainability and the Environment
Reference35 articles.
1. Takai, H., et al., Concentrations and Emissions of Airborne Dust in Livestock Buildings in Northern Europe, Journal of Agricultural Engineering Research, 70 (1998), 1, pp. 59-77 2. Wathes, C. M., Ventilation in Stables, Farm Buildings and Engineering, 6 (1989), pp. 21-25 3. Banhazi, T. M., et al., Identification of the Risk Factors for High Airborne Particle Concentrations in Broiler Buildings Using Statistical Modeling, Biosystems Engineering, 101 (2008), 1, pp. 100-110 4. Donham, K. et al., Environmental and Health Studies of Farm Workers in Swedish Swine Confinement Buildings, Occupational and Environmental Medicine, 46 (1989), 1, pp. 31-37 5. Harry, E. G., Air pollution in Farm Buildings and Methods of Control - Review, Avian Pathology 7 (1978), 4, pp. 441-454
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|