Sensitivity and specificity of D-dimer tests comparing to the ultrasound examination of deep vein thrombosis

Author:

Markovic Dragan1,Vasic Dragan1ORCID,Basic Jelena2ORCID,Tanaskovic Slobodan3,Cvetkovic Slobodan1,Rancic Zoran4

Affiliation:

1. Faculty of Medicine, Belgrade + Clinical Centre of Serbia, Clinic for Vascular and Endovascular Surgery, Belgrade

2. Rudolfstiftung, Department of Cardiology, Vienna, Austria

3. Faculty of Medicine, Belgrade + Institute for Cardiovascular Diseases “Dedinje”, Clinic for Vascular Surgery, Belgrade

4. University Hospital Zurich, Department of Cardiovascular Surgery, Zurich, Switzerland + University of Zurich, Faculty of Medicine, Zurich, Switzerland

Abstract

Introduction/Objective. Untreated deep vein thrombosis (DVT) is associated with a high risk of pulmonary embolism (PE), and false diagnosis of DVT results in unnecessary anticoagulant therapy, with a risk of bleeding. Accurate diagnosis of DVT and prompt therapy are essential to reduce the risk of thromboembolic complications. The aim of our study was to evaluate the sensitivity and specificity of three D-dimer tests (DD PLUS, HemosIL, and VIDAS) comparing to compression ultrasonography (CUS) examination. Methods. We observed 350 patients, some with different risk factors. The patients underwent the same protocol (evaluation of the patient?s history, physical examination, and D-dimer testing), and CUS was used as a reference for all the patients. According to Wells score, the patients were divided into groups with low, moderate, and high pretest probability (PTP). Results. Most of the examined patients were with moderate PTP. The CUS showed that there was the highest number of examined patients without DVT. Most of the examined patients with a positive CUS finding had proximal iliac and femoral DVT. VIDAS test was positive in the highest percentage in the group of patients with CUS-documented thrombosis. Conclusion. All three D-dimer tests used in our study had similar sensitivity and specificity. However, VIDAS test had higher levels of positive and negative predictive values comparing to the others. The comparison of three D-dimer tests by an ROC curve showed that VIDAS test has the highest overall statistical accuracy of all three D-dimer tests.

Publisher

National Library of Serbia

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3