Abstract

Cathodic voltammetric behaviors of drospirenone and ethinylestradiol were used for the simultaneous determination of both drugs in bulk and in pharmaceutical formulation (Yasmin® tablets) without the interference of excipients. The determinations were made on hanging mercury dropping electrode using square-wave technique in a voltammetric cell containing 10 mL of 0.04 mole/L Britton-Robinson. After every aliquot addition, the solution was stirred for 10 s at 1000 rpm, rested for 10 s then square wave voltammetry mode was ramped from +100 to -1700 mV with scan rate of 100 mV/s, pulse amplitude of 50 mV and measurement time of 5 ms. Several factors such as pH, type of supporting electrolyte, pulse amplitude and scan rate were studied to optimize the condition for voltammetric determination of these drugs. With optimized experimental parameters, a good linearity was obtained for both drugs over a range of 1.36×10-6 to 1.91×10-7 mole/L and 6.75×10-8 to 6.07×10-7 mol/L of drospirenone and ethinylestradiol, respectively. Characterization of the proposed method was done according to International Conference on Harmonization, Q2B: Validation of Analytical procedures. The proposed method was statistically compared with the reference method and the results revealed no significant difference regarding accuracy and precision.

Publisher

European Journal of Chemistry

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3