Validation of a Vision-Based, Three-Dimensional Facial Imaging System

Author:

Ayoub A.1,Garrahy A.2,Hood C.2,White J.3,Bock M.4,Siebert J. P.5,Spencer R.6,Ray A.7

Affiliation:

1. Oral and Maxillofacial Surgery, Glasgow Dental Hospital and School, Glasgow, Scotland

2. Pediatric Dentistry, Glasgow Dental Hospital and School, Glasgow, Scotland

3. Orthodontics, Glasgow Dental Hospital and School, Glasgow, Scotland

4. Department of Statistics, University of Glasgow, Glasgow, Scotland

5. Vision and Graphics Laboratory (3D-MATIC), Department of Computing Science, University of Glasgow, Glasgow, Scotland

6. School of Manufacturing and Mechanical Engineering, University of Birmingham, Birmingham, England

7. Plastic Surgery, Canniesburn Hospital, Glasgow, Scotland

Abstract

Objective The aim of this study was to assess the accuracy of a newly developed three-dimensional (3D) imaging system in recording facial morphology. Methods Twenty-one infants with cleft lip each had a full-face alginate impression taken at the time of primary lip repair, and a stone cast was constructed from each impression. Five anthropometric points were marked on each cast. Each cast was digitized, and the 3D co-ordinates of the five points were obtained using a co-ordinate measuring machine (CMM, Ferranti) of documented accuracy (9.53 μm). Each cast was scanned in four positions using a computerized stereophotogrammetry (C3D) system. The five points were located on the 3D images, and their 3D co-ordinates were extracted by three operators. The co-ordinate systems produced by C3D were aligned, via translation and rotation, to match the CMM co-ordinate system using partial ordinary procrustes analysis. The displacements of the adjusted C3D co-ordinates from the reference co-ordinates were then measured. Three different types of errors were identified: operator, system, and registration errors. Results Operator error was within 0.2 mm of the true co-ordinates of the landmarks. C3D was accurate within 0.4 mm. The average displacement of points over the 21 casts at four positions for the three operators was 0.79 mm (median 0.68). Conclusions The presented 3D imaging system is reliable in recording facial deformity and could be utilized in recording cleft deformities and measuring the changes following surgery

Publisher

SAGE Publications

Subject

Otorhinolaryngology,Oral Surgery

Cited by 129 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3