Three-Dimensional Analysis of Maxillary Dental Casts Using Fourier Transform Profilometry: Precision and Reliability of the Measurement

Author:

Trefný Pavel1,Šmahel Zbynek23,Formánek Pavel4,Peterka Miroslav5

Affiliation:

1. Institute of Dental Research, General Faculty Hospital, Prague

2. Faculty of Natural Sciences and Chairman of the Committee for Postgraduate Studies in Anthropology at Charles University, Prague

3. Institute of Experimental Medicine, Academy of Sciences of the Czech Republic, Prague

4. Institute of Thermomechanics, Academy of Sciences of the Czech Republic, Prague

5. Department of Teratology, Institute of Experimental Medicine, Academy of Sciences of the Czech Republic, Prague

Abstract

Objective Fourier transform profilometry was used for the three-dimensional measurement of maxillary dental casts to analyze the size and shape of the palate. The objective of this study was to test the accuracy of the measuring system and determine the precision and reliability of the measurement Methods Images of dental casts were analyzed using newly developed measuring software. Based on five landmarks located on the alveolar ridge, the measuring software constructed 10 transversal sections of the palate. In each section profile, the width, area, and 23 height variables were assessed. Subjects Maxillary dental stone casts of 25 healthy girls, 14.1 to 15.3 years of age, were studied. Results The technical error of measurement exceeded 5% of the size of the measurement only in variables with means less than approximately 3 mm. In fact, such small absolute dimensions were exhibited only by the palate height in anterior profile 2 and the palate height at the margins of other profiles. Reliability of the measurements was found to be very high for the width and area of the profiles. For height measurements, the coefficient of reliability was slightly lower at the profile margins than near the midline. Nevertheless, only three height variables showed a coefficient of reliability lower than 0.90. The coefficients of reliability of other height measurements of profiles 3 through 10 were only sporadically lower than 0.97. Conclusion With regard to the accuracy of the measuring system as well as the precision and reliability of the measurement, this method proved to be a suitable tool for studying palatal morphology.

Publisher

SAGE Publications

Subject

Otorhinolaryngology,Oral Surgery

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3