Abstract
In Nnewi, Anambra State Nigeria, twenty vertical electrical sounding (VES) were performed to delineate vulnerability and transmissivity of identified aquifer within the study area. Hydraulic parameters (transverse resistance, longitudinal conductivity, hydraulic conductivity and transmissivity) were delineated from geoelectrical parameters (depth, thickness, and apparent resistance). The geo- parameters of the aquifer: apparent resistance from 1000.590 to 1914.480, thickness from 42.850 – 66.490 m and 65.530 to 100.400 m of depth. The estimated hydraulic parameters of the aquifers are transverse resistance 54264.383 - 104568.898 Ωm, longitudinal conductance 0.029 – 0.062 mho, hydraulic conductivity 0.664 – 2.015 m/day and transmis- sivity between 4.167 and 13.963 m2/day. All aquifers have poor protective capacity, 40 percent of the aquifers have low classification with smaller withdrawal potential for local groundwater supply, while 60 percent of the delineated aquifer has intermediate classification and withdrawal potential for local groundwater supply. Due to its groundwater supply potential and protective capacity, the eastern part of the study area has stronger groundwater potential.
Publisher
Oles Honchar Dnipropetrovsk National University
Subject
General Earth and Planetary Sciences,General Environmental Science
Cited by
11 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献