Cardiac visceral fat volume estimation from low-dose chest computed tomography: a study with a designed beating heart phantom

Author:

Chernina V. Yu.ORCID,Kulberg N. S.ORCID,Aleshina O. O.ORCID,Korb T. A.ORCID,Blokhin I. A.ORCID,Morozov S. P.ORCID,Gombolevskiy V. A.ORCID

Abstract

Background: Since 2017, a pilot project for lung cancer screening by chest low dose computed tomography (LDCT) has been implemented in Moscow. Patients to be included into the screening have risk factors for ischemic heart disease (IHD). The association between epicardial adipose tissue (EAT) volume and coronary artery atherosclerosis, IHD, and atrial fibrillation has been demonstrated previously.Aim: To demonstrate the feasibility of LDCTbased EAT volumetry using a  dynamic (contracting) heart phantom.Materials and methods: The study was performed with the designed dynamic heart phantom and chest phantom in two stages. At stage I, two adipose tissue pieces were scanned inside and outside the chest phantom using CT and LDCT. At stage II, the dynamic heart phantom was scanned outside and inside the chest phantom. In addition, we scanned the heart phantom with a  coronary calcium phantom. The contracting heart phantom was developed within three months. All scans of the phantom were performed within one day. We determined the adipose tissue thresholds in LDCT and the EAT volumetric error with both chest CT and LDCT. Measurements of the adipose tissue volumes were performed by the radiologist twice with semi-automatic software.Results: The results of stage I helped to identify optimal density thresholds for LDCT-based adipose tissue volumetry in lung cancer screening, ranging from -250 HU to -30 HU. The stage II results showed that for all heart phantom scanning variants, the average EAT volumetry error did not exceed 5%, except for the case of contracting heart phantom with added coronary calcium in a chest phantom with body mass index (BMI) 29 (-5.92%). Adding the coronary calcium phantom to the heart phantom in LDCT increased the error by an average of 4% in BMI 23 and BMI 29 chest phantoms.Conclusion: LDCT-based EAT volumetry with fat density threshold from -250 HU to -30 HU is feasible in lung cancer screening, including patients with coronary calcium. However, considering the phantom design, further patient studies, and correlation of EAT volumes between LDCT for lung cancer screening and сoronary CT angiography are required.

Publisher

Moscow Regional Research and Clinical Institute (MONIKI)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3