THE HYBRID SUBISCHIAL SOCKET FOR PERSONS WITH TRANSFEMORAL AMPUTATION: GAIT PARAMETERS AND CLINICAL ASSESSMENT OF A CASE SERIES

Author:

Pellegrini RobertoORCID,Denza GabrieleORCID,Brunelli StefanoORCID,Zenardi DanieleORCID,Imperio MatteoORCID,Vannozzi GiuseppeORCID,Traballesi MarcoORCID

Abstract

BACKGROUND: The subischial socket interface design is a promising new shape of socket for persons with transfemoral amputation. Typically, the proximal trim line is located distal to the ischial tuberosity, improving comfort in prosthetic users without interfering with gait parameters compared to Ischial Containment Socket (ICS). No studies have investigated the performances of a subischial sockets with suction suspension system. A new subischial socket (Hybrid Subischial Socket - HySS) combined with a hypobaric passive suspension system has been recently developed. OBJECTIVE: To assess the effects of HySS in terms of comfort, hip range-of-motion and gait parameters. METHODOLOGY: Three persons with transfemoral amputation were tested first using their usual ICS and then after one month of continuous use of HySS. FINDINGS: The following parameters improved in all participants using HySS: 1) hip range-of-motion, 2) walking speed and distance, 3) Timed-Up-and-Go-Test time, 4) stride length, 5) double support duration, 6) peak value of hip extension during stance, 7) satisfaction with the prosthesis. CONCLUSION: These findings suggest that the use of HySS could allow improvements for prosthetic use. Layman’s Abstract This case series describes the effects of a subischial socket combined with a hypobaric suction suspension system for persons with transfemoral amputation. This socket has the proximal trim line located distally to the ischial tuberosity and it does not interact with the pelvis. The results have shown that this socket may improve the overall prosthetic comfort, hip range of motion and some gait parameters compared to the conventional ischial containment socket. Article PDF Link: https://jps.library.utoronto.ca/index.php/cpoj/article/view/36252/28095 How To Cite: Pellegrini R, Denza G, Brunelli S, Zenardi D, Imperio M, Vannozzi G, Traballesi M. The hybrid subischial socket for persons with transfemoral amputation: gait parameters and clinical assessment of a case series. Canadian Prosthetics & Orthotics Journal. 2021;Volume 4, Issue 1, No.9. https://doi.org/10.33137/cpoj.v4i1.36252 Corresponding Author: Stefano Brunelli, MDFondazione Santa Lucia, Scientific Institute for Research, Hospitalization and Health Care, Rome, Italy.E-Mail: s.brunelli@hsantalucia.itORCID ID: https://orcid.org/0000-0002-5986-1564  

Publisher

University of Toronto Libraries - UOTL

Subject

General Materials Science

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3