Longevity of Bonding of Self-adhesive Resin Cement to Dentin

Author:

Simões TC1,Luque-Martinez ÍV2,Moraes RR3,Sá ATG4,Loguercio AD5,Moura SK6

Affiliation:

1. Tânia Christina Simões, DDS, MS, PhD, Restorative Dentistry, University North of Paraná, Londrina, Brazil

2. Issis Virgínia Luque-Martinez, Dentistry Academic Unit, Faculty of Medicine, Pontificia Universidad Católica de Chile, Santiago, Chile

3. Rafael R de Moraes, DDS, MS, PhD, professor, Restorative Dentistry, School of Dentistry, Federal University of Pelotas, Pelotas, Brazil

4. André Tomazini Gomes de Sá, PhD, professor, Prosthodontics, Federal Institute of Paraná, Londrina, Brazil

5. Alessandro D Loguercio, DDS, MS, PhD, professor, Restorative Dentistry, State University of Ponta Grossa, Ponta Grossa, Brazil

6. Sandra Kiss Moura, DDS, MDS, PhD, professor, Restorative Dentistry, University North of Paraná, Londrina, Brazil

Abstract

SUMMARY Objective: To evaluate the effect of root dentin treatment on the bonding of self-adhesive resin cement after 24 hours and after 6 months. Methods: A total of 48 single-rooted premolars were endodontically treated and divided into four groups (n=12): Adper Scotchbond Multi-Purpose + RelyX ARC (ARC); RelyX U200 (U200); EDTA + RelyX U200 (EU200); and phosphoric acid (H3PO4) + RelyX U200 (HU200). After filling the roots, an Exacto No. 2 fiber post was cleaned, treated with silane (60 seconds), positioned, and light cured (LED; 60 seconds at 1200 mW/cm2). After storage (37°C/24 h), the roots were cut to obtain two discs (1 mm) of each third. They were stored in distilled water (24 hours at 37°C); one disc of each root-third was subjected to the push-out test (0.5 mm/min) at 24 hours and the other disc after six months of water storage (37°C). The data on the root-thirds were averaged for statistical purposes. The average values of bond strength (MPa) were analyzed by two-way analysis of variance and post hoc Student-Newman-Keuls (5%). Results: There were statistical differences for the treatment of dentin (p<0.001), for time (p=0.003), and the interaction of treatment and time (p=0.017). After 24 hours, we observed lower bond strength in the HU200 group when compared with other groups (ARC, U200, and EU200). After six months, HU200 showed the lowest bond strength. Higher strengths were observed for EU200 and U200 similarly, which were higher than ARC. Conclusion: The bonding of the self-adhesive resin cement varied over time in the tested groups.

Publisher

Operative Dentistry

Subject

General Dentistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3