Effect of Successive In-office Bleaching Sessions on the Surface Properties, Substance Loss, Biaxial Flexural Strength, and Reliability of CAD-CAM Monolithic Materials

Author:

Queiroz JFC1,Fernandes L2,Dovigo LN3,Fonseca RG4

Affiliation:

1. João Fernando Carrijo Queiroz, postgraduate student, São Paulo State University (UNESP), School of Dentistry, Araraquara, São Paulo, Brazil

2. Leandro Fernandes, Ing, MSc, PhD, São Paulo State University (UNESP), School of Dentistry, Araraquara, São Paulo, Brazil

3. Lívia Nordi Dovigo, DDS, MSc, PhD, São Paulo State University (UNESP), School of Dentistry, Araraquara, São Paulo, Brazil

4. *Renata Garcia Fonseca, DDS, MSc, PhD, São Paulo State University (UNESP), School of Dentistry, Araraquara, São Paulo, Brazil

Abstract

SUMMARY Little is known about the effects of in-office bleaching on the surface properties and on other aspects of CAD-CAM monolithic materials, especially when successive bleaching sessions are conducted. This study evaluated the effect of up to three successive in-office bleaching sessions on the microhardness, roughness, topography, substance loss, biaxial flexural strength (BFS), and reliability of CAD-CAM monolithic materials. Disks from Lava Ultimate (LU), Vita Enamic (VE), and IPS Empress CAD (EMP) were fabricated and submitted to one, two, and three bleaching sessions. In-office bleaching was performed with 40% hydrogen peroxide and each session consisted of three applications of 20 minutes each. The analyses regarding the aforementioned parameters were assessed before and after the first, second, and third bleaching sessions, except for BFS, which was evaluated at the baseline and after the third session. Weibull modulus was calculated from the BFS data. Bleaching decreased the microhardness of LU and VE from the third and second sessions, respectively, and affected neither the roughness nor the BFS of the three materials. However, in LU, it decreased the reliability and caused topographic changes, which were accentuated by the increase in the number of sessions. In general, LU and EMP showed, respectively, the highest and the lowest substance losses. Successive in-office bleaching sessions with the use of the protocol of the present study should be avoided in LU and VE.

Publisher

Operative Dentistry

Subject

General Dentistry

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370