In Vitro Evaluation of the Stabilization Time of Chemical Bonds During Setting Reaction and Microhardness of Preheated Glass-Ionomer Cements

Author:

Lopes LCP,Terada RSS,de Castro-Hoshino LV,de Oliveira BMB,Pascotto RC,Baesso ML,Tabchoury CPM,Sato F,Nicholson JW,Sidhu SK

Abstract

SUMMARY Objectives: To evaluate the effect of preheating glass-ionomer cement (GIC) restorative materials on stabilization time (ST) of their metal carboxylate bonds and on microhardness. Methods and Materials: Two conventional high-viscosity GICs, Ketac Universal (3M ESPE) and Equia Forte (GC), were evaluated. The thermographic camera was used to measure the temperature inside the glass-ionomer cement capsules before and after heating. The preheating of capsules was performed at 54°C for 30 seconds in a commercial device. Characterization of ST in the GICs was determined by Fourier Transform Infrared (FTIR) spectroscopy. For this, 10 samples of each material were prepared, five in the non-preheated group (control) and five with preheating. FTIR spectra were obtained 10 minutes after mixing (control group) or after heating and then every 10 minutes for 120 minutes. For the microhardness test, 20 cylindrical specimens (3 mm height x 6 mm diameter) were prepared for each material (10 preheated, 10 control). The microhardness was determined at three time intervals: 10 minutes after mixing, after the ST as detected through the FTIR part of the study, and after one week. Knoop microhardness was assessed using a diamond indenter with a 25 g load and 15 seconds dwell time. Results: Ketac Universal showed an increase in temperatures of 15.7°C for powder and 3.6°C for liquid, while Equia Forte showed 16.4°C for powder and 8.5°C for liquid. FTIR spectra indicated that preheating reduced the ST for Equia Forte but increased it for Ketac Universal. Preheating increased the initial microhardness (T1) of Equia Forte. With maturation over one week, it was observed that preheating significantly improved the microhardness of both materials compared with the control specimens. Conclusion: Preheating influenced the ST and the microhardness of Ketac Universal and Equia Forte. The ST and microhardness of Ketac Universal increased after seven days, whereas Equia Forte showed a reduced ST and increased microhardness from the outset.

Publisher

Operative Dentistry

Subject

General Dentistry

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3