Filler Content, Surface Microhardness, and Rheological Properties of Various Flowable Resin Composites

Author:

Jager S1,Balthazard R2,Dahoun A3,Mortier E4

Affiliation:

1. Stéphanie Jager, DDS, PhD, Faculty of Dentistry, Department of Pediatric Dentistry, Nancy, France

2. Rémy Balthazard, DDS, PhD, Faculty of Dentistry, Department of Conservative Dentistry, Nancy, France

3. Abdesselam Dahoun, Professor, Si2M Department, UMR CNRS 7198, Jean Lamour Institute, Nancy, France

4. Eric Mortier, DDS, PhD, Faculty of Dentistry, Department of Conservative Dentistry, Nancy, France

Abstract

SUMMARY Objectives: The objectives of this study were to determine the filler content, the surface microhardness (at baseline and after immersion in water for 2 years), and the rheological properties of various flowable resin composites. Methods: Three flowable resin composites (Grandioso Heavy Flow [GHF], Grandio Flow [GRF], Filtek Supreme XTE Flow [XTE]), one pit and fissure sealant resin composite (ClinPro [CLI]), and three experimental flowable resin composites with the same matrix and a variable filler content (EXPA, EXPB, EXPC) were tested. The filler content was determined by calcination. The Vickers surface microhardness was determined after polymerization and then after immersion in distilled water at 37°C for 7, 60, 180, 360, and 720 days. The rheological measurements were performed using a dynamic shear rheometer. Results: The determined filler contents differed from the manufacturers' data for all the materials. The materials with the highest filler content presented the highest microhardness, but filler content did not appear to be the only influencing parameter. With respect to the values recorded after photopolymerization, the values were maintained or increased after 720 days compared with the initial microhardness values, except for GHF. For the values measured after immersion for 7 days, an increase in microhardness was observed for all the materials over time. All the materials were non-Newtonian, with shear-thinning behavior. At all the shear speeds, GRF presented a lower viscosity to GHF and XTE. Conclusions: GRF presented a low viscosity before photopolymerization, associated with high filler content, thereby providing a good compromise between spreadability and mechanical properties after photopolymerization.

Publisher

Operative Dentistry

Subject

General Dentistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3