Does Shortened Application Time Affect Long-Term Bond Strength of Universal Adhesives to Dentin?

Author:

Saikaew P1,Matsumoto M2,Chowdhury AFMA3,Carvalho RM4,Sano H5

Affiliation:

1. Pipop Saikaew, DDS, MSc, Mahidol University, Operative Dentistry and Endodontics, Bangkok, Thailand

2. Mariko Matsumoto, DDS, PhD, Hokkaido University, Restorative Dentistry, Sapporo, Japan

3. A.F.M. Almas Chowdhury, DDS, PhD candidate, Hokkaido University, Restorative Dentistry, Sapporo, Japan

4. Ricardo M Carvalho, DDS, PhD, professor, UBC, Oral Biological and Medical Sciences, Faculty of Dentistry, Vancouver, BC, Canada

5. Hidehiko Sano, DDS, PhD, professor, Division of Oral Health Science, Department of Restorative Dentistry, Sapporo, Japan

Abstract

SUMMARY Objective: This study evaluated the effect of shortened application time on long-term bond strength with universal adhesives. Methods and Materials: Three universal adhesives were used: Clearfil Universal Bond (CU, Kuraray Noritake Dental Inc, Tokyo, Japan), Scotchbond Universal Adhesive (SB, 3M ESPE, St Paul, MN, USA) or G-Premio Bond (GP, GC Corp, Tokyo, Japan). Sixty molars were cut to expose midcoronal dentin and prepared with a regular diamond bur. Each adhesive was applied either according to the manufacturer's instruction or with shortened time. Specimens were stored in distilled water at 37°C for 24 hours and then cut into resin-dentin sticks. Microtensile bond strength (μTBS) was tested after either 24 hours or 1 year of water storage. Data were analyzed by the three-way ANOVA and Duncan tests (α=0.05). Fracture modes were analyzed under a scanning electron microscope (SEM). One dentin stick per group was selected after fracture mode analysis and further observed using transmission electron microscopy (TEM). Six additional dentin discs were prepared and conditioned with each adhesive under the different application time to observe the adhesive-smear layer interaction by SEM. Results: Shortened application time affected the μTBS (p<0.001) while storage time did not affect bond strength (p=0.187). A significant effect of shortened application time on μTBS was observed in the CU at 1 year and in the GP at both storage times. Conclusions: One-year storage time had no effect on the μTBS of universal adhesives to bur-cut dentin. The performance of universal adhesives can be compromised when applied using a shortened application time.

Publisher

Operative Dentistry

Subject

General Dentistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3